• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Thu, 02.05.24

Search results


November 2022
Regev Landau MD, Ana Belkin MD, Sapir Kon-Kfir MD, Nira Koren-Morag PhD, Avishay Grupper MD, David Shimunov MD, Ben-Ami Sela PhD, Ehud Grossman MD, Gadi Shlomai MD, Avshalom Leibowitz MD

Background: Most dyspneic patients in internal medicine departments have co-morbidities that interfere with the clinical diagnosis. The role of brain natriuretic peptide (BNP) levels is well-established in the acute setting but not in hospitalized patients.

Objectives: To evaluate the additive value of BNP tests in patients with dyspnea admitted to medical wards who did not respond to initial treatment.

Methods: We searched the records of patients who were hospitalized in the department of internal medicine D at Sheba Medical Center during 2012 and were tested for BNP in the ward. Data collected included co-morbidity, medical treatments, diagnosis at presentation and discharge, lab results including BNP, re-hospitalization, and mortality at one year following hospitalization.

Results: BNP results were found for 169 patients. BNP was taken 1.7 ± 2.7 days after hospitalization. According to BNP levels, dividing the patients into tertiles revealed three equally distributed groups with a distinctive character. The higher tertile was associated with higher rates of cardiac co-morbidities, including heart failure, but not chronic obstructive pulmonary disease. Higher BNP levels were related to one-year re-hospitalization and mortality. In addition, higher BNP levels were associated with higher rates of in-admission diagnosis change.

Conclusions: BNP levels during hospitalization in internal medicine wards are significantly related to cardiac illness, the existence of heart failure, and patient prognosis. Thus, BNP can be a useful tool in managing dyspneic patients in this setting.

January 2019
Ayelet Grupper MD, Moshe Shashar MD, Talia Weinstein MD PhD, Orit Kliuk Ben Bassat MD, Shoni Levy MD, Idit F. Schwartz MD, Avital Angel MD, Aharon Baruch MD, Avishay Grupper MD, Gil Chernin MD and Doron Schwartz MD

Background: Dialysate purity contributes to the inflammatory response that afflicts hemodialysis patients.

Objectives: To compare the clinical and laboratory effects of using ultrapure water produced by a water treatment system including two reverse osmosis (RO) units in series, with a system that also includes an ultrapure filter (UPF).

Methods: We performed a retrospective study in 193 hemodialysis patients during two periods: period A (no UPF, 6 months) and period B (same patients, with addition of UPF, 18 months), and a historical cohort of patients treated in the same dialysis unit 2 years earlier, which served as a control group.

Results: Mean C-reactive protein, serum albumin and systolic blood pressure worsened in period B compared to period A and in the controls.

Conclusions: A double RO system to produce ultrapure water is not inferior to the use of ultrapure filters.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel